Cement industry - filtration plant of Intensiv-Filter GmbH & Co. KG
TULONA® filter medium NX.8655-1/01 T74 |
 |
 |
 |
| Process |
Dust collection after a lime calcination process |
| Temperature |
80-180°C |
| Flue gas flow rate |
120.000 Am³/h |
| Filter area |
1583 m² |
| Filter system |
pulse jet, on-line |
| Dust load in raw gas |
10 g/m³ |
| Dust load in clean gas |
≤5 mg/m³ |
|
 |
|
|
|
|
|
 |
|
 |
|