TULONA® filter medium: DO.723401-3/02
Technical Polyacrylnitrile
Process |
dust collection in an asphalt-mixing plant |
Temperature |
125 °C, 140 °C max. |
Flue gas flow rate |
80.000 m³/h |
Filter area |
712 m² |
Filter system |
pulse jet, on-line |
Dust load raw gas |
250 g/m³ |
Dust load clean gas |
≤ 20 mg/m³ |